Common Troubleshooting on 300 Series Automatic Applicators
By following this guide, you can effectively troubleshoot and resolve common issues with 300 Series Applicator pump and system, ensuring reliable operation and performance.
Pump will not run. |
1. No voltage to THS. |
1. Check for short, low voltage, and replace fuse if necessary. |
Pump runs but will not prime. |
1. Air leak in intake. |
1. Tighten fittings on intake side. |
Pump does not develop |
1. Air leaks or clogs on inlet. |
1. Tighten or clean filter bowl |
Moisture reading errors |
1. Wire disconnected or bad connection between moisture disc and THS |
1. Reconnect wire. |
Moisture Reading Erratic |
1. Check all wiring connections for corrosion or poor contact. |
1. Apply dielectric grease to all connections. |
Product is less than actual product used. |
1. Voltage supplied to flow meter is less than 11 volts. |
1. Check for a min of 11 volts supplied at THS. |
Product shown is 10% different than actual product used. |
1. High voltage supplied to the meter. |
1. Check voltage at THS Max of 18 volts. |
System leaks product out of tips after shut down. |
1. Dirty or defective solenoid |
1. Clean or Replace. |
System does not pause at the end of a row. |
1. Short in cable. |
1. Replace cable. |
Solenoid will not pulse. |
1. Dirty or plugged |
1. Clean or Replace |
Bluetooth Receiver lights will not illuminate |
1. Bluetooth receiver not connected |
1. Check connections and voltage. Minimum 12.5V needed.
|
|
Red Light – The Bluetooth receiver has power |